HVAC & BMS
Refrigeration
Fire & Security
Service & Solutions
Energy Solutions
Global Marine and Navy
Product Information
Case Studies
Local contact
Global WorkPlace Solutions
| ► | Integrated HVAC Systems |
| ► | BMS products |
| ▼ | Refrigeration products |
| • | Refrigeration Components |
| • | Modulating Water Valves |
| • | Field Controllers |
| • | Condenser Fan Speed Controllers |
| • | Flow and Float Controls |
| • | Pressure Controls |
| • | P232 |
| • | P233 |
| • | P20 |
| • | P28 |
| • | P45 |
| • | P74 |
| • | P48 |
| • | P735 |
| • | P736 |
| • | P77 |
| • | P78 |
| • | P100 |
| • | H735 |
| • | Pressure Transducers |
| • | Temperature Controls |
| ► | Security products |
PRESSURE CONTROLS
P28
Oil Protection
These controls measure the pressure differential between the pressure generated by the oil pump and the refrigerant pressure at the crankcase.
A built-in time delay switch allows for pressure-pick up on start and avoids nuisance shutdowns on pressure drops of short duration during the running cycle.
When the compressor is started, the time delay switch is energised. If the net oil pressure does not build up within the required time limit, the time delay switch trips to stop the compressor. If the net oil pressure rises within the required time after the compressor starts, the time delay switch is automatically de-energised and the compressor continues to operate normally. If the net oil pressure should drop below setting (scale pointer) during the running cycle, the time delay switch is energised and, unless the net oil pressure returns to cut-in point within the time delay period, the compressor will be shut down, and have to be manual reset.
The compressor can never run longer than the predetermined time on low oil pressure.
Controls are available only for manual reset after cut-out.
FEATURES
• Heavy duty pressure elements
• Safety lock-out with trip-free manual reset
• Ambient compensated timing
• Dust-tight Penn switch
APPLICATION
These oil protection controls are designed to give protection against low net lube oil pressure
on pressure lubricated refrigeration compressors.
| UK | |
| Email: Graham.Young@jci.com | Telephone: +44 (0) 1795 472361 |
| Austria |
|
| Email: Eva.Reischl@jci.com | Telephone: +43 1 661 36 254 |
Belux |
|
| Email: Dietmar.Docus@jci.com | Telephone: +32 2 709 43 23 |
| Czech Republic |
|
| Email: Jan.Kratina@jci.com | Telephone: +420 725 709 876 |
Hungary |
|
| Email: Zoltan.Pato@jci.com | Telephone: +361 459 3734 |
Ireland |
|
| Email: Andrew.Mcevitt@jci.com | |
| Italy |
|
| Email: Alessandro.Picciau@jci.com | Telephone: +39 02 280 42 443 |
Netherlands |
|
| Email: products.nl@jci.com | Telephone: +31 (0) 183 66 76 33 |
Poland |
|
| Email: WARSAW-CG-EUR-PL@jci.com |
Telephone: +48 22 518 19 00 |
Russia |
|
| Email: ref-russia@jci.com | Telephone: +7 495 232 66 60 |
| South Africa |
|
| Email: Neil.Cameron@jci.com | Telephone: +27 11 921 7100 |
Switzerland |
|
| Email: Detlef.Sopart@jci.com |
